Configuring the Switch

Configure Threshold Alerts

A threshold alert notifies users when the transmit (Tx) or receive (Rx) throughput
reaches specified values for specific switch ports or port types, (E_Ports, F_Ports
or FL_Ports).
You are notified of a threshold alert by:
Use the Threshold Alerts option on the Configure menu to configure the
following:
You can configure up to 16 alerts, and any number of alerts can be active at one
time.
Use the following procedures to create a new threshold alert, or to modify,
activate, deactivate, or delete an alert.
124
An attention indicator (yellow triangle) that displays on the port in the
Hardware View.
An attention indicator (yellow triangle) that displays in the Alert column of
the Port List View.
An attention indicator (yellow triangle) that displays by the Threshold Alerts
field in the Port Properties dialog box.
Detailed threshold alert data recorded in the Threshold Alert Log.
Name for the alert.
Type of threshold for the alert (Rx, Tx, or either).
Active or inactive state of the alert.
Threshold criteria:
— Percent traffic capacity utilized. This is the percent of the port's
throughput capacity achieved by the measured throughput. This setting
constitutes the threshold value. For example the value of 50 means that
the port's threshold is reached when throughput reaches 50% of port
capacity.
— Time interval during which throughput is measured and alert notification
can occur.
— The maximum cumulative time that throughput percentage can be
exceeded during the set time interval before an alert is generated.
Ports for which you are configuring threshold alerts.
Edge Switch 2/24 Product Manager User Guide