Table 42 Assigned element type codes
Code
0.1.
0.2.
0.3.
0.4.
0.6
0.7.
0.C.
0.F.
1.0.
1.1.
1.2.
1.
8.0
8.2.
8.7.
1
Does not generate a condition report. However, for any error, you should record the error code. Then, implement the
recommended corrective action.
Drive conditions
The format of a disk drive condition report is 0.1.en.ec, where:
0.1. is the disk drive element type number
en. is the two-character disk drive element
ec is the error code
A direct correlation exists between the disk drive element number and the bay number. However,
no direct correlation exists between the disk drive
enclosure physical address. The Fibre Channel drive enclosure physical address is assigned by
negotiation during system initialization.
The following sections define the disk drive error codes.
0.1.en.01 CRITICAL condition—Drive configuration or drive link rate
As each drive spins up and comes on-line, the EMU determines if the drive is Fibre Channel
compatible and can operate at the link rate (1 Gbps or 2 Gbps) established by the I/O module.
If either of these conditions are not met, the EMU issues the condition report 0.1.en.01.
The corrective actions for these conditions are:
When the drive is not Fibre Channel-compatible you must install a Fibre Channel compatible
drive or a drive blank.
When the drive is Fibre Channel-compatible, the EMU compares the drive link rate with the
I/O module link rate, the loop link rate.
Disk Drives
Power Supplies
Blowers
Temperature Sensors
1
Audible Alarm
EMU
1
Controller OCP LCD
Transceivers
1
Language
Communication Port
Voltage Sensors
Current Sensors
1
Drive Enclosure
Drive Enclosure Backplane
I/O Modules
Element
bay
number and the device Fibre Channel drive
Correcting errors 123