Table 12 Audible alarm sound patterns (continued)
Condition type
NONCRITICAL
INFORMATION
Legend

Controlling the audible alarm

You can control the alarm with the push-button. This process includes muting, enabling, and
disabling. When an error condition exists, the alphanumeric display reads Er, the alarm sounds,
and you can:
Correct all errors, thereby silencing the alarm until a new error occurs.
Mute, or temporarily disable, the alarm by pressing and holding the bottom push-button. The
alarm remains off until another error occurs, or until you enable (unmute) the alarm. When a
new error occurs, the alarm sounds and the push-button indicator is off.
Using the mute feature ensures that you are aware of the more severe errors and provides
you with the capability of correcting them promptly.
Disable the alarm to prevent any error condition from sounding the alarm.
NOTE:
Disabling the alarm does not prevent the EMU alphanumeric display from displaying Er,
nor does it prevent HP Command View EVA from displaying the error condition report.
When the alarm is enabled (on), the bottom push-button status indicator is off.

Enabling the audible alarm

To enable the alarm:
1.
Press and release the bottom push-button until the alphanumeric display is Au.
2.
Press and hold the top push-button until the alphanumeric display is a Flashing oF (Audible
Alarm Off).
NOTE:
display to toggle between On and oF. Press and release the top push-button to cause the
display to select the next state.
3.
Press and release the top push-button to change the display to a flashing On (Audible Alarm
On).
4.
Press and release the bottom push-button to accept the change and to display Au. The bottom
push-button indicator is now off.

Muting or unmuting the audible alarm

You may want to mute the alarm in the following situations:
The error does not require immediate corrective action.
You cannot correct the error at this time. For example, the error may require a replacement
part.
To mute the
audible
Cycle 1
Alarm On
When the alarm display is flashing, press and hold the top push-button to cause the
alarm:
Cycle 2
Alarm Off