Porsche 928 - WORKSHOP MANUAL 1977 Workshop Manual page 436

Table of Contents

Advertisement

87
Air
Conditioner
928
CHECKING FLAP POSITION PROGRAM
Flap A - recirculating
air
Flap C - closed
Flap
D - closed
Flap
E - open
Water valve
- closed
3
1 - Switch
for
fresh-air
blower
2 - Slide
control
for
temperature
adjustment
3 - Slide
control
for
air
distribution
Testing
preconditions:
Vacuum system
leaktight
and
depressurized.
Switch
ignition
on. Open central
vent.
l.Set
slide
2 to max. cooling
out-
put.
Set slide
3 to "Off".
The positions
of the flaps
must be
as follows:
2.Set
slide
3 for
air
supply
to
central
vent.
Flap A - fresh
air.
The other
flaps
remain
at
positions
as for
check
1.
3.Set
slide
3 for
air
supply
from
bottom
vent.
Flap
D - opens.
4.Set
slide
3 for
air
supply
from
upper/lower
vents.
Flap C opens.
5.Set
slide
3 for
air
distribution
from top vent.
Flap
D closes.
a
a
a7 - 108
Checking
Flap Position
Program
Printed
in Germany

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1986 9281985 928928

Table of Contents