Configuring Transit Node - H3C LS-3100-52P-OVS-H3 Operation Manual

S5500-ei series ethernet switches
Table of Contents

Advertisement

To do...
Specify the current device as
the master node of the ring,
and specify the primary port
and the secondary port
Configure the timer for the
RRPP domain
Enable the RRPP ring
Return to system view
Enable RRPP
Before specifying RRPP rings for an RRPP domain, you must specify protected VLANs for the
domain.
Before specifying rings for an RRPP domain, you can delete or modify the protected VLANs
configured for the RRPP domain; after specifying rings for an RRPP domain, you can delete or
modify the protected VLANs configured for the RRPP domain, however, you cannot delete all the
protected VLANs configured for the domain.
Deleting an RRPP domain deletes its protected VLANs at the same time.
The protected-vlan command configures protected VLANs for an RRPP domain by referencing
MSTIs to which the protected VLANs are mapped. You can use the display stp
region-configuration command to view the VLAN-to-MSTI mappings. For detailed information
about VLAN-to-MSTI mapping configuration, refer to MSTP Configuration in the Access Volume.
The control VLAN configured for an RRPP domain must be a new one.
Control VLAN configuration is required for configuring an RRPP ring.
To use the undo rrpp domain command to remove an RRPP domain, you must ensure the RRPP
domain has no RRPP ring.
Before removing or modifying the control VLAN of an RRPP domain, make sure that the RRPP
domain is not configured with any RRPP ring.

Configuring Transit Node

Follow these steps to configure transit node:
To do...
Enter system view
Create an RRPP domain and
enter its view
Use the command...
ring ring-id node-mode master
[ primary-port interface-type
interface-number ]
[ secondary-port interface-type
interface-number ] level
level-value
timer hello-timer hello-value
fail-timer fail-value
ring ring-id enable
quit
rrpp enable
Use the command...
system-view
rrpp domain domain-id
1-12
Remarks
Required
Optional
By default, the Hello timer
value is 1 second and the Fail
timer value is 3 seconds.
Required
By default, the RRPP ring is
disabled.
Required
By default, RRPP is disabled.