H3C S3610 Series Ethernet Switches
LED
DC-input
power LED
7-segment
numerical
display
10Base-T/10
0Base-TX
Ethernet port
status LED
Mark
Status
Solid green
RPS
Solid yellow
OFF
In the progress of POST
POST failure
Unit
Loading software
Fan failure
Green
Yellow
Speed
Flashing yellow
(at 3 Hz)
OFF
Green
Duplex
Yellow
Flashing yellow
(at 3 Hz)
OFF
1-11
Chapter 1 Product Overview
Meaning
The DC input and the AC
part are all normal.
The DC input is normal; the
AC part is abnormal or the
AC input is disconnected.
The DC input is
disconnected.
The number of current POST
item is displayed.
The number of failed POST
item is displayed.
The short lines are lighted
clockwise during the loading.
"F" is displayed.
The port works at 100 Mbps;
when it receives/sends data,
the LED flashes quickly.
The port works at 10 Mbps;
when it receives/sends data,
the LED flashes quickly.
The port fails the POST.
The port is disconnected.
The port works in full duplex
mode; when it
receives/sends data, the
LED flashes quickly.
The port works in half duplex
mode; when it
receives/sends data, the
LED flashes quickly.
The port fails the POST.
The port is disconnected.