WebBlocker
To configure WebBlocker:
1. To connect to the System Status page, type
of the Firebox X Edge trusted interface.
The default URL is: https://192.168.111.1
2. From the navigation bar, select WebBlocker > Settings.
The WebBlocker Settings page appears
3. Select the Enable WebBlocker check box to activate WebBlocker for HTTP or HTTPS.
4. If you want to allow users to bypass WebBlocker if they know the full access password, select the
Enable WebBlocker override check box. Type a password in the Full Access Password field, and then
type the same password again in the Confirm Password field.
The full access password gives access to all web sites until the inactivity timeout is reached or until an
authenticated user logs out. This feature operates only with HTTP proxy policies.
5. Type a number, in minutes, in the Inactivity Timeout field.
The Inactivity Timeout field shows the length of time the full access password is active if no web
browsing is done. If a user types the full access password and no HTTP or HTTPS traffic is sent from that
user's computer for the length of time set in the Inactivity Timeout field, WebBlocker rules start again.
The value can be from 1 to 1440 minutes.