The amount of
system memory has
changed.
Time-of-day
clock stopped.
Time-of-day not
set - please run
SETUP program.
Timer chip
counter 2 failed.
TPM or TCM
configuration
operation
honored. System
will now reset.
46
About Your System
Causes
Memory has been added or
removed or a memory
module may be faulty.
Faulty battery or faulty chip. See "Troubleshooting the
Incorrect Time or Date
settings; faulty system
battery.
Faulty system board.
A Trusted Platform Module
(TPM) or China Trusted
Platform Module (TCM)
configuration command has
been entered. The system
will reboot and execute the
command.
Corrective Actions
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module. See
"Troubleshooting System
Memory" on page 159.
System Battery" on page 156.
Check the Time and Date
settings. See "Using the
System Setup Program and
UEFI Boot Manager" on
page 53. If the problem
persists, replace the system
battery. See "System Battery"
on page 131.
See "Getting Help" on
page 185.
Information only.