Dell PowerEdge E05S Owner's Manual page 27

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge E05S:
Table of Contents

Advertisement

Code
Text
E1421 CPU #
initialization
error. Power
cycle AC.
E1422 CPU # machine
check error.
Power cycle
AC.
E1610 Power Supply
# (#### W)
missing.
Check power
supply.
E1614 Power Supply
# (#### W)
error. Check
power supply.
E1618 Predictive
failure on
Power Supply
# (#### W).
Check PSU.
E161C Power Supply
# (#### W)
lost AC
power. Check
PSU cables.
Causes
The system BIOS reported a
processor initialization error.
The system BIOS reported a
machine check error.
Specified power supply
removed or is missing from
the system.
Specified power supply
failed.
A power supply fan failure,
an over-temperature
condition, or power supply
communication error caused
the predictive warning of an
impending power supply
failure.
Specified power supply is
installed but lost its AC
input.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
See "Troubleshooting
Power Supplies" on
page 157.
See "Troubleshooting
Power Supplies" on
page 157.
See "Troubleshooting
Power Supplies" on
page 157.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 157.
About Your System
27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e05s001Poweredge r815

Table of Contents