Dell PowerEdge E05S Owner's Manual page 48

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge E05S:
Table of Contents

Advertisement

Message
Unsupported CPU
combination
Unsupported CPU
stepping
detected.
Unsupported DIMM
detected. The
following DIMM
has been
disabled: x
Unsupported
memory
configuration.
DIMM mismatch
across slots
detected:
x,x,...
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
Warning: Front
Control Panel is
not installed.
Warning! No micro
code update
loaded for
processor n.
48
About Your System
Causes
Processor(s) is not supported
by the system.
Invalid memory
configuration. The system
will run but with the
specified memory module
disabled.
Invalid memory
configuration. Memory
modules are mismatched in
the specified slots.
A fatal system error occurred
and caused the system to
reboot.
The control panel is not
installed or has a faulty cable
connection.
Micro code update failed.
Corrective Actions
Install a supported processor
or processor combination.
See "Processors" on page 125.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 93.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 93.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 151 for
any faulty components
specified in the SEL.
Install the control panel, or
check the cable connections
between the control panel
board and the system board.
See "Control Panel
Assembly" on page 139.
Update the BIOS. See
"Getting Help" on page 185.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e05s001Poweredge r815

Table of Contents