Dell PowerEdge E05S Owner's Manual page 29

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge E05S:
Table of Contents

Advertisement

Code
Text
E1710 I/O channel
check error.
Review &
clear SEL.
E1711 PCI parity
error on Bus
## Device ##
Function ##.
PCI parity
error on Slot
#. Review &
clear SEL.
E1712 PCI system
error on Bus
## Device ##
Function ##.
PCI system
error on Slot
#. Review &
clear SEL.
Causes
The system BIOS reported
an I/O channel check.
The system BIOS reported a
PCI parity error on a
component that resides in
PCI configuration space at
bus ##, device ##,
function ##.
The system BIOS reported a
PCI parity error on a
component that resides in
the specified slot.
The system BIOS reported a
PCI system error on a
component that resides in
PCI configuration space at
bus ##, device ##,
function ##.
The system BIOS reported a
PCI system error on a
component that resides in
the specified slot.
Corrective Actions
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 185.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 166.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 166.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 166.
Remove and reseat the
expansion-card riser that
provides the specified slot.
See "Expansion Cards and
Expansion-Card Risers"
on page 107. If the
problem persists, the riser
card or system board is
faulty. See "Getting Help"
on page 185.
About Your System
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e05s001Poweredge r815

Table of Contents