10 Rotate the socket-release lever down until it snaps into place. See
Figure 3-24.
NOTE:
processor that consumes additional power. The new heat sink may not appear
different than the original one; however, it has improved thermal dissipation
specifications and must be used.
11 Using a clean lint-free cloth, remove the thermal grease from the heat sink.
CAUTION:
in contact with and contaminating the processor socket.
12 Keeping the heat sink pin aligned with the slot on the system board,
place the heat sink on the processor. See Figure 3-23.
13 Using a #2 Phillips screwdriver, tighten the two heat-sink retention
screws. See Figure 3-23.
14 If applicable, replace the cooling fan assembly. See "Installing the Cooling
Fan Assembly" on page 104.
15 Replace the cooling shroud. See "Installing the Cooling Shroud" on
page 89.
16 If applicable, slide the front chassis assembly back. See "Front-Chassis
Assembly" on page 90.
17 Close the system. See "Closing the System" on page 77.
18 Reconnect your system and peripherals to their electrical outlets, and turn
on the system.
19 Press <F2> to enter the System Setup program, and check that the processor
information matches the new system configuration. See "Entering the
System Setup Program" on page 54.
20 Run the system diagnostics to verify that the new processor operates
correctly.
For information about running the diagnostics, see "Running the
Embedded System Diagnostics" on page 172.
130
Installing System Components
Your kit may contain a replacement heat sink if you are installing a
Applying too much thermal grease can result in excess grease coming