Dell PowerEdge E05S Owner's Manual page 45

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge E05S:
Table of Contents

Advertisement

Message
Read fault.
Requested sector
not found.
SATA Port x
device not found.
SATA port x
device auto-
sensing error.
SATA port x
device
configuration
error.
SATA port 0
device failure.
Requested sector
not found.
Seek error.
Seek operation
failed.
Shutdown
failure.
Causes
The operating system cannot
read from the hard drive,
optical drive, or USB device,
the system could not find a
particular sector on the disk,
or the requested sector is
defective.
There is no device connected
to the specified SATA port.
The drive connected to the
specified SATA port is faulty.
Faulty hard drive, USB
device, or USB medium.
General system error.
Corrective Actions
Replace the optical medium,
USB medium or device.
Ensure that the SAS
backplane, USB, or SATA
cables are properly
connected. See
"Troubleshooting a USB
Device" on page 152,
"Troubleshooting an Optical
Drive" on page 163, or
"Troubleshooting a Hard
Drive" on page 164 for the
appropriate drive(s) installed
in your system.
Information only.
Replace the faulty drive.
Replace the USB medium or
device. Ensure that the USB
or SAS backplane cables are
properly connected. See
"Troubleshooting a USB
Device" on page 152 or
"Troubleshooting a Hard
Drive" on page 164 for the
appropriate drive(s) installed
in your system.
See "Getting Help" on
page 185.
About Your System
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e05s001Poweredge r815

Table of Contents