Code
Text
E1119 Chipset #
temp out of
range. Check
motherboard
heatsinks.
E1210 Motherboard
battery
failure.
Check
battery.
E1211 RAID
Controller
battery
failure.
Check
battery.
E1216 3.3V
Regulator
failure.
Reseat PCIe
cards.
E1219 Disk
Backplane
power
failure.
Check BP
power cable.
E122C CPU Power
Fault. Power
cycle AC.
24
About Your System
Causes
Chipset temperature
reached a point outside the
allowed range.
CMOS battery is missing or
the voltage is outside the
allowable range.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
3.3 V voltage regulator
failed.
Storage backplane voltage
regulator failed.
A power fault was detected
when powering up the
processor(s).
Corrective Actions
See "Troubleshooting
System Cooling
Problems" on page 157.
See "Troubleshooting the
System Battery" on
page 156.
Reseat the RAID battery
connector. See "Internal
Dual SD Module
(Optional)" on page 123
and "Troubleshooting
System Cooling
Problems" on page 157.
Remove and reseat the
PCIe expansion cards. If
the problem persists, see
"Troubleshooting
Expansion Cards" on
page 166.
Remove and reconnect
the backplane power
cable.
If the problem persists,
see "Getting Help" on
page 185.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.

Hide quick links: