Code
Text
E2010 Memory not
detected.
Inspect
DIMMs.
E2011 Memory
configuration
failure.
Check DIMMs.
E2012 Memory
configured
but unusable.
Check DIMMs.
E2013 BIOS unable
to shadow
memory. Check
DIMMs.
E2014 CMOS RAM
failure.
Power cycle
AC.
E2015 DMA
Controller
failure.
Power cycle
AC.
E2016 Interrupt
Controller
failure.
Power cycle
AC.
Causes
No memory detected in the
system.
Memory detected, but is not
configurable. Error detected
during memory
configuration.
Memory configured, but is
unusable.
The system BIOS failed to
copy its flash image into
memory.
CMOS failure. CMOS RAM
not functioning properly.
DMA controller failure.
Interrupt controller failure.
Corrective Actions
Install memory or reseat
the memory modules. See
"Installing Memory
Modules" on page 97 or
"Troubleshooting System
Memory" on page 159.
See "Troubleshooting
System Memory" on
page 159.
See "Troubleshooting
System Memory" on
page 159.
See "Troubleshooting
System Memory" on
page 159.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
About Your System
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e05s001Poweredge r815