Code
Text
E122D Memory
Regulator #
Failed.
Reseat DIMMs.
E122E On-board
regulator
failed. Call
support.
E1243 CPU # VCORE
Regulator
failure.
Contact
Support.
E1310 Fan ## RPM
exceeding
range. Check
fan.
E1313 Fan
redundancy
lost. Check
fans.
E1314 Critical
system
cooling loss.
Check fans.
E1410 System Fatal
Error
detected.
Causes
One of the memory voltage
regulators failed.
One of the on-board voltage
regulators failed.
Processor voltage regulator
failed.
RPM of specified fan is
outside the intended
operating range.
The system is no longer fan
redundant. Another fan
failure would put the system
at risk of over-heating.
All fans have been removed
from the system.
A fatal system error
detected.
Corrective Actions
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 159.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Reseat the processor. See
"Troubleshooting the
Processors" on page 168.
If the problem persists,
see "Getting Help" on
page 185.
See "Troubleshooting
System Cooling
Problems" on page 157.
Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan"
on page 158.
Ensure that the fans are
properly installed. See
"Troubleshooting a Fan"
on page 158.
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
About Your System