Code
Text
E1620 Power Supply
# (#### W) AC
power error.
Check PSU
cables.
E1624 Lost power
supply
redundancy.
Check PSU
cables.
E1629 Power
required >
PSU wattage.
Check PSU and
config.
E1631 System power
draw exceeded
threshold.
Contact
support.
E1632 FailSafe
event.
Contact
support.
28
About Your System
Causes
Specified power supply's AC
input is outside the
allowable range.
The power supply subsystem
is no longer redundant. If
the remaining power supply
fails, the system will shut
down.
The system configuration
requires more power than
the power supplies can
provide, even with
throttling.
Processor and memory
throttling is not sufficient to
keep system power
consumption below the
maximum safe level with
the current power supply
configuration.
The processors and memory
have been throttled to keep
system power consumption
below the maximum safe
level with current power
supply configuration.
Corrective Actions
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 157.
See "Troubleshooting
Power Supplies" on
page 157.
Turn off power to the
system, check if adequate
power is supplied to the
system. See the Getting
Started Guide for
information on the
System power
requirements.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 185.

Hide quick links: