Dell PowerEdge E05S Owner's Manual page 36

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge E05S:
Table of Contents

Advertisement

Code
Text
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
E2112 Memory spared
on Card x
DIMM ##.
Power cycle
AC.
I1910 Intrusion
detected.
Check chassis
cover.
I1911 LCD Log Full.
Check SEL to
review all
Errors.
I1912 SEL full.
Review &
clear log.
36
About Your System
Causes
The memory module in slot
"##" has had a multi-bit
error (MBE).
The system BIOS disabled
memory single-bit error
(SBE) logging and will not
log any more SBEs until the
system is rebooted. "##"
represents the memory
module implicated by the
BIOS.
The system BIOS spared the
memory because it
determined that the
memory has too many
errors.
System cover removed.
LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
The SEL is full of events
and is unable to log any
more.
Corrective Actions
Reseat the memory
module in its socket.
If the problem persists,
see "Troubleshooting
System Memory" on
page 159.
Reseat the memory
module in its socket.
If the problem persists,
see "Troubleshooting
System Memory" on
page 159.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 159.
Replace the chassis cover
or ensure the chassis cover
is properly installed. See
"Closing the System" on
page 77.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
Check the SEL for more
information and then
clear the SEL.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e05s001Poweredge r815

Table of Contents