3-2
Dell PowerEdge 4300 Systems Service Manual
1-1-3
NVRAM write/read
failure
1-1-4
BIOS checksum
failure
1-2-1
Programmable
interval-timer failure
1-2-2
DMA initialization
failure
1-2-3
DMA page register
write/read failure
1-3-1
Main-memory
refresh verification
failure
1-3-2
No memory installed
1-3-3
Chip or data line fail-
ure in the first 64 KB
of main memory
1-3-4
Odd/even logic fail-
ure in the first 64 KB
of main memory
1-4-1
Address line failure
in the first 64 KB of
main memory
1-4-2
Parity failure in the
first 64 KB of main
memory
2-1-1
Bit failure in the first
through
64 KB of main
2-4-4
memory
Replace the system board.
This fatal error usually requires that
you reflash the BIOS firmware. If
the problem persists, replace the
system board.
Replace the system board.
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still per-
sists, replace the system board.
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still per-
sists, replace the system board.