Hardware reference
Item
Transmission format, databit length
Transmission format, stop bit
Transmission format, parity bit
Transmission mode
Transmission protocol
Galvanic isolation
Communication buffers
Flow control
Terminator
Maximum cable length
HARDWARE REFERENCE MANUAL
Specification
7 or 8 bit
1 or 2 bit
Even/odd/none
•
RS232C: Point-to-point (1:1)
•
RS422/485: Point-to-multipoint (1:N)
•
Host link master protocol
•
Host link slave protocol
•
ModbusRTU slave protocol
•
ASCII general purpose
RS422/485 connector only
254 bytes
None
Yes, selected by switch
•
RS232C: 15 m
•
RS422/485: 100 m