Omron TJ2-MC64 Hardware Reference Manual page 109

Trajexia machine control system
Hide thumbs Also See for TJ2-MC64:
Table of Contents

Advertisement

Hardware reference
Dipswitch
The following table shows the dipswitch settings of the SI-T/V7 Unit.
/i
Name
Label
Status
Baud rate
S1-1
on
Data length
S1-2
on
Station
S1-3
off
address
on
Maintenance
S1-4
off
on
1. For maintenance. Always leave this switch off.
Rotary switch
The following table shows the rotary switch settings of the SI-T/V7 Unit.
/i
Label
Status
Function
S2
0 to F
Set the 1st digit of the station number. Invalid if
the maximum number of units including the S1-
3 is 20 or 3F.
/i
S1-3
S2
Station number
off
0
Fault
off
1
21
off
2
22
HARDWARE REFERENCE MANUAL
Function
10 Mbps (MECHATROLINK-II)
32-byte data transmission
(MECHATROLINK-II)
Set the 10th digit of the station number to 2.
Invalid if the maximum number of units including
the S2 of the rotary switch is 20.
Set the 10th digit of the station number to 3.
Invalid if the maximum number of units including
the S2 of the rotary switch is 3F.
1
Normally off
Not used
Factory setting
1
S1-3
S2
Station number
on
0
30
on
1
31
on
2
32
fig. 46
1
2
3
4
OFF
fig. 47
0
8
104