Omron NT21 Reference Manual page 346

Programmable terminals
Hide thumbs Also See for NT21:
Table of Contents

Advertisement

Input of Numeric Values and Character Strings
Cases Where Multiple Numeral Setting Input Fields Exist on a Screen (Without
Cursor Moving Keys)
Setting
Reference: If a screen has multiple numeral setting fields or character string input fields, the
Operation
1, 2, 3...
Displayed
Order
Key
numeric
value
Initial value
0000.000
1
0001.000
1
2
0015.000
5
3
0152.000
2
4
0152.000
B
The following describes the procedure for inputting a numeric value at a screen
that has multiple numeric key type numeral setting fields. The explanation is giv-
en for the operation that uses the input key – control keys to specify the input field
instead of the touch switch cursor moving keys.
For the operation using the cursor moving keys, refer to Cases When Multiple
Numeral Setting Input Fields Exist on a Screen (With Cursor Moving Keys)
(page 333).
Here, the basic method for inputting numeric values is not explained: the ex-
planation concentrates on how the multiple numeral setting input fields should
be handled. For the numeric value input procedure and other related operations,
refer to Inputting Numeric Values Using the Input Key – Control on the Same
Screen (page 328).
When creating a screen using the Support Tool, set the elements indicated be-
low that are used to specify the active numeral input field as well as the regular
control keys that are used to input the numeric value.
Touch switch input key – control
HOME, , ,
,
,
active input field must be specified using these keys: HOME, , ,
1. Display the screen where a numeral setting input field is registered.
2. Specify the objective numeral setting input field using the input key – control
(HOME, , ,
,
For the procedure for specifying the objective input field, refer to Specifying
the Objective Numeral Setting Input Field Using Input Key – Control (page
332).
3. Input a numeric value using the input key – control.
For the procedure for inputting a numeric, refer to Inputting Operation Using
Touch Switches (page 329).
4. Press the ENT key of the input key – control or the
When the input is confirmed, the input numeric value is stored to a numeral
memory table entry. Then, the occurrence of a change in the contents of the
numeral memory table entry is notified to the host via the PT status notify
area (page 61).
Displayed
Order
Key
numeric
value
5
0152.000
6
4
1524.000
7
1524.000
.
8
1524.100
1
9
1524.130
3
, and
,
,
).
Section
3-7
Displayed
Order
Key
numeric
value
10
1524.130
11
0000.000
.
12
0000.900
9
13
0000.950
5
14
0000.950
,
,
,
key to confirm the input.
331
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt631Nt31 seriesNt21 seriesNt631 series

Table of Contents