Graphs
166
Settings (properties of each broken line)
Start Table
First numeral memory table entry number of the numeral
*1
Entry
memory table entries used to display the broken line.
Range: 0 to 1998
*1
No. of points
Number of vertices in the broken line display (one memory table
entry is used for each vertex)
NT21:
NT31/NT31C:
NT631/NT631C: 2 to 512
Interval Type
Interval between numeral memory table entries in the broken
line.
Even/Uneven (cannot resize) (0 to size in the broken line
graph Direction – 1)
Line
Color
Display color of the broken line (Colors other than black and
white are available with the NT31C and NT631C only.)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
Style
Line type used for the broken line graph
Solid line:
Broken line:
1-dot chain line:
2-dot chain line:
*2
100%
(Specify 100% value using either of Table Entry or Value.)
Table Entry
Numeral memory table entry number checked to find the
100% value for percentage calculations
@ Designate the number of the numeral memory table entry
that stores the 100% value.
Range: 0 to 1999
Value
Checked to find the 100% value for percentage calculations
@ Designate the 100% value (default: 100)
Range: –2147483648 to 2147483647
*2
0%
(Specify 0% value using either of Table Entry or Value.)
Table Entry
Numeral memory table entry number checked to find the 0%
value for percentage calculations
@ Designate the number of the numeral memory table entry
that stores the 0% value.
Range: 0 to 1999
Value
Checked to find the 0% value for percentage calculations
@ Designate the 0% value (default: 0)
Range: –2147483648 to 2147483647
*2
–100%
(Specify –100% value using either of Table Entry or Value.)
Table Entry
Numeral memory table entry number checked to find the
–100% value for percentage calculations
@ Designate the number of the numeral memory table entry
that stores the –100% value.
Range: 0 to 1999
Value
Checked to find the –100% value for percentage calculations
@ Designate the –100% value (default: –100)
Range: –2147483648 to 2147483647
*1: When making the setting, ensure that the total of the Start Table Entry and No. of
Points does not exceed the maximum table entry.