3-1 Installing the PT
Precautions
for Correct Use
3-1-6

Peripheral Device Connection Limitations

Select one of the following combinations when devices requiring power supply are con-
nected to port A, port B, and an Expansion Interface Unit on the PT. Use a 5-V Bar Code
Reader with a current consumption of 250 mA or the equivalent.
When a Bar Code Reader and the NS-AL002 are connected to ports
A and B at the same time
When a Bar Code Reader and the CJ1W-CIF11 are connected to
ports A and B at the same time
When a Bar Code Reader and the NT-AL001 are connected to ports
A and B at the same time
When the CJ1W-CIF11 and CJ1W-CIF11 are connected to ports A
and B at the same time
When the CJ1W-CIF11 and NS-AL002 are connected to ports A and
B at the same time
When the CJ1W-CIF11 and NT-AL001 are connected to ports A and
B at the same time
When two NT-AL001s are connected to ports A and B at the same
time
When a Bar Code Reader is connected to port A or B
When the CJ1W-CIF11 is connected to port A or B
When the NS-AL002 is connected to port A or B
When the NT-AL001 is connected to port A or B
When Bar Code Readers are connected to ports A and B at the same
time
When the NT-AL001 and NT-AL002 are connected to port A or B at
the same time
3-8
Ground correctly to prevent malfunctions caused by noise.
Port A and B connection combinations
Expansion Interface Unit
(NS-CA001, NS-CA002,
NS-CLK21)
Cannot be used
Cannot be used
Cannot be used
Can be used
Can be used
Cannot be used
Cannot be used
Can be used
Can be used
Can be used
Can be used
Cannot be used
Cannot be used

Advertisement