Omron NS - SETUP Setup Manual page 154

Ns-series programmable terminals
Hide thumbs Also See for NS - SETUP:
Table of Contents

Advertisement

5-1 Connecting to Host Via Ethernet
Example: Setting 130.58.17.32 (Decimal)
This address will be 82.3A.11.20 in hexadecimal, so the switch would be set as shown in the
following table.
Switch Setting
Local IP address in
hexadecimal
Local IP address in
decimal
Reference
Ethernet Connectors
This is the connector used to connect the transceiver cable to the Ethernet.
• Electrical characteristics: Conforms to IEEE802.3 standards.
• Lock structure:
5-10
SW1
8
• When using automatic generation (default method) for converting addresses, set the
same value for the node number as that set for SW7 and SW8, and set the other host
ID fields to 0. The ERC indicator will flash if the value of the IP address host ID does
not correspond to the node number value.
• Set the subnet mask in the CPU Bus Unit Setup Area using the CX-Programmer.
CS1W-ETN01
Connec-
tor Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Hood
SW2
SW3
SW4
2
3
A
82
3A
130
58
Conforms to IEEE802.3 standards for Slide latches.
Signal name
Signal ground
Collision detection signal +
Send data +
Signal ground
Receive data +
Voltage common
Power ground (common
with signal ground)
Not used.
Signal ground
Collision detection signal −
Send data −
Signal ground
Receive data −
Transceiver power
Signal ground
Not used.
Frame ground
SW5
SW6
SW7
SW8
1
1
2
0
11
20
17
32
Abbreviation
GND
COL+
TX+
GND
RX+
VC
GND
COL−
TX−
GND
RX−
VP
GND
FG
Signal direction
Input
Output
Input
Input
Output
Input

Advertisement

Table of Contents