6-5 Setting Passwords
• Settings for the Password Function
The following table describes the password function's setting items.
Level
Time Out
Timeout (min)
Switch Screen when cancel-
ing the authentication
Switch Screen No.
Reference
Precautions
for Safe Use
6-38
Setting item
OFF
ON
ON
OFF
ON
OFF
The password settings can also be made from the CX-Designer.
• When changing passwords, do not reset the PT or turn OFF the power until
the write operation has been completed (i.e., the Write Button has returned
to the status before being pressed). If the password is not saved properly,
the screen may malfunction.
• If the password is forgotten, it cannot be checked from the PT. Check the
password using the CX-Designer.
Press the OFF (password) or ON (password with levels)
Button to select the function.
Requires a password input before allowing operations on a
password-protected functional object.
Requires a password input for level authentication. During a
session from authentication to cancellation, the user only
can perform operations on functional objects that are al-
lowed for the password level that was input at the start of
the session. The user cannot perform operations on func-
tional objects at higher levels.
Click the ON or OFF Button to specify whether authentica-
tion is automatically canceled (timed out) after a set time
has elapsed.
This option can be set when the password with levels func-
tion has been turned ON.
A user is automatically timed out if there are no functional
object operations within the timeout time.
Authentication is not automatically canceled. To cancel au-
thentication, press a command button set for cancellation.
When the Time Out Option is set to ON, this setting speci-
fies the timeout time in minutes (1 to 60 minutes).
Click the ON or OFF Button to specify whether the screen is
automatically switched to a specified screen when a user
logs out.
This option can be set when the password with levels func-
tion has been turned ON.
The screen is switched to the specified Switch Screen No.
when authentication is canceled.
The screen is not switched when authentication is canceled.
If switching the screen when authentication is canceled has
been turned ON, the screen is changed to the screen num-
ber set here when authentication is canceled.
Function