Timing Charts
Power
Start signal
Gate
Reset
999999
Set value (SV 2)
Forecast value (SV 1)
0
OUT1
OUT2
The names in parentheses are used for the absolute value setting.
Power
Start signal
Gate
Reset
999999
Set value (SV 2)
Forecast value (SV 1)
0
OUT1
OUT2
The names in parentheses are used for the absolute value setting.
Note: Forecast Value = Set Value - Forecast Set Value
The forecast set value is used to set the deviation for the set value.
Self-diagnostic Function
The following displays will appear if an error occurs.
Main display
Sub-display
e1
Not lit
e2
Not lit
e2
sum
Note: This includes times when the life of the EEPROM has expired.
46
2-stage Digital Timer
A Mode: Signal ON delay (Timer resets when power comes ON.)
F-1 mode: Cumulative (Timer does not reset when power comes ON.)
Error
CPU
OFF
Memory error (RAM)
OFF
Memory error (EEP)
OFF
(See note)
H5CX-B
Timing starts when the start signal turns ON.
While the start signal is ON, the timer starts when the power
turns ON or when the reset input turns OFF.
A sustained control output is used.
Timing stops when the time is up.
Basic Operation
Start signal input
Forecast output
(Control output 1)
Control output
(Control output 2)
*
Output is instantaneous when the set value is 0.
**
Start signal input is disabled during timing.
Start signal enables timing (timing is stopped when the
start signal is OFF or when the power is OFF).
A sustained control output is used.
Timing continues even after the time is up.
Basic Operation
Start signal input
Forecast output
(Control output 1)
Control output
(Control output 2)
*
Output is instantaneous when the set value is 0.
Output status
Correction method
Either press the reset key or reset the
power supply.
Reset the power supply.
Reset to the factory settings using
the reset key.
Power
**
Timing
OUT1
OUT2
The names in parentheses are used for the
absolute value setting.
Power
Timing
Timing
Sustained
OUT1
OUT2
The names in parentheses are used for
the absolute value setting.
Set value after
reset
No change
No change
0