List of Settings
Fill in your set values in the set value column of the following tables and utilize the tables for quick reference.
Timer/Twin Timer Selection Mode
Parameter
Parameter
name
func
Timer/Twin Tim-
er selection
dip
DIP switch moni-
tor
Settings for Timer Operation
Run Mode when Output Mode Is Not Z
Parameter name
Present value,
Set value
set value
Present value
Run Mode when Output Mode = Z
Parameter name
Present value,
Cycle time
ON duty ratio
ON duty ratio
Present value,
Present value
cycle time
Present value
Function Setting Mode
Parameter name
Time range
Timer mode
Output mode
Output time
Input signal width
NPN/PNP input mode
Display color
Key protect level
Setting range
tim/twin
on/off
Parameter
0.00 to 99.99 (Time range: --,--s)
---
0.0 to 999.9 (Time range: ---,-s)
---
0 to 9999 (Time range: ----s)
---
0:00 to 99:59 (Time range: --min--s)
---
0.0 to 999.9 (Time range: ---,-min)
---
0 to 9999 (Time range: ----min)
---
0:00 to 99:59 (Time range: --h--min)
---
0.0 to 999.9 (Time range: ---,-h)
---
0 to 9999 (Time range: ----h)
---
0.000 to 9.999 (Time range: -,---s)
---
---
Same as set value
Parameter
0.00 to 99.99 (Time range: --,--s)
---
0.0 to 999.9 (Time range: ---,-s)
---
0 to 9999 (Time range: ----s)
---
0:00 to 99:59 (Time range: --min--s)
---
0.0 to 999.9 (Time range: ---,-min)
---
0 to 9999 (Time range: ----min)
---
0:00 to 99:59 (Time range: --h--min)
---
0.0 to 999.9 (Time range: ---,-h)
---
0 to 9999 (Time range: ----h)
---
0.000 to 9.999 (Time range: -,---s)
---
0 to 100
---
---
Same as cycle time above
---
Same as cycle time above
Parameter
timr
--.--s/---.-s/----s/--min--s/---.-min/----min/--
h--min/---.-h/----h/-.---s
timm
up/down
outm
a/a-1/a-2/a-3/b/b-1/d/e/f/=
otim
hold/0.01 to 99.99
iflt
20ms/1ms
imod
npn/pnp
colr
red/org/r-o/o-r
kypt
kp-1/kp-2/kp-3/kp-4/kp-5
Default value
tim
off
Setting range
Setting range
Setting range
Multifunction Digital Timer
Unit
---
---
Default value
Unit
0.00
s
0.0
s
0
s
0:00
min; s
0.0
min
0
min
0:00
h; min
0.0
h
0
h
0.000
s
Same as left
Same as left
Default value
Unit
0.00
s
0.0
s
0
s
0:00
min; s
0.0
min
0
min
0:00
h; min
0.0
h
0
h
0.000
s
0
%
Same as left
Same as left
Same as left
Same as left
Default
Unit
value
--.--s
---
up
---
a
---
hold
s
20ms
---
npn
---
red
---
kp-1
---
H5CX-A/-L
Set value
Set value
Set value
Set value