Using Advanced Functions - Omron H5S Datasheet

Digital time switch
Hide thumbs Also See for H5S:
Table of Contents

Advertisement

Using Advanced Functions

About Advanced Functions
Set the advanced functions as required to perform more advanced
operation. Outlines of the advanced functions are provided on the
following pages.
Refer to the Instruction Manual enclosed with the H5S for details.
Initial Setting Mode
Weekly, 2 Circuits
Yearly, 2 Circuits
Press
TIME ADJ
for 3 s or more.
Program setting mode
Press briefly
TIME ADJ
<2-circuit
>
models
P1
P1
or
P2
P2
RUN
RUN
Press briefly
TIME ADJ
<4-circuit
>
models
Press briefly
PRGM
TIME ADJ
RUN
Press briefly
TIME ADJ
Press briefly
TIME ADJ
Press briefly
TIME ADJ
Press briefly
TIME ADJ
Press briefly
TIME ADJ
Press briefly
TIME ADJ
Yearly, 4 Circuits
Initial setting mode
F1:Next operation display
.
F2:Input selection
*2-circuit models only
.
*Only when "totl"
F3:Total time alarm
is selected in F2.
.
*Only when "totl"
F4:Total count alarm
is selected in F2.
.
F5:Date format
*Yearly models only
selection
.
F6:Summer time
(DST) adjustment *Yearly models only
.
F7:Summer time
*Yearly models only
schedule selection
Only when "auto"
is selected in F6.
.
F8:Season switching *Yearly models only
.
F9:Period of season *Yearly models only
Only when "on"
is selected in F8.
.
Time Counter/Total Counter Display
(F2, F3, F4)
Yearly, 2 Circuits
Yearly, 2 Circuits
This function displays the total elapsed time and total input count for
an external input.
The alarm indicator can also be displayed if an alarm value has been
set.
Alarm
indicator
Time counter display
(Example shows display
when the total elapsed time
is 30,000 hours.)
Note: For display details, refer to Display Switching on page 22.
Input selection (F2)
• Set Input selection (F2) in initial setting mode to Time Counter/Total
Counter.
Shaded portion indicates
blinking of the indicator.
1. Press
display to totl.
2. Press
Alarm for time counter (F3)
Shaded portion indicates
1. The display will automatically change
blinking of the indicator.
to the alarm setting screen 2 s after
switching to F3.
Press the
h
m
Note: The default setting
2. Press
is 0.0 h (no alarm
display).
*
Pressing
key that was last pressed.
Alarm for total counter (F4)
Shaded portion indicates
1. The display will automatically change
blinking of the indicator.
to the alarm setting screen 2 s after
switching to F4.
Press the
h
m
Note: The default setting
2. Press
is 0 (no alarm
display).
*
Pressing
key that was last pressed.
Digital Time Switch
Total counter display
(Example shows display
when the total input
count is 500,000.)
h
or
m
to change the
WRITE
to enter the setting.
h
or
m
.
Key: Increments in units of 1,000 h*
Key: Increments in units of 10 h*
WRITE
to enter the setting.
decrements the value of the
h
m
or
.
Key: Increments in units of 10,000*
Key: Increments in units of 100*
WRITE
to enter the setting.
decrements the value of the
H5S
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents