Omron H5S Datasheet page 5

Digital time switch
Hide thumbs Also See for H5S:
Table of Contents

Advertisement

■ Operation
Item
Operation method
Operation period
Display
Min. setting unit
Number of
Weekly program
steps that
(See note 1.)
can be set
Yearly program
Number of
settable yearly
temporary
holiday settings
Note: 1. Depending the operation, the following steps can be used for weekly programs.
Timer operation: 2 steps
Pulse-output operation: 1 step
Cyclic operation: 4 steps
2. When the season switching setting is not being used.
3. When the season switching setting is being used.
■ Operation Functions
Item
Weekly 2-circuit Models (H5S-W@2)
Weekly timer
Timer operation
operation
ON
Weekly pulse-
Pulse output operation
output
operation
ON
Weekly cyclic
Cyclic operation
operation
Start
ON
Yearly timer
---
operation
Yearly pulse-
---
output
operation
Temporary
Sets temporary holidays (non-operating days) without having to revise the existing program.
holiday setting
For details, refer to Setting Temporary Holidays (Weekly) and Setting Temporary Holidays (Yearly) on page 20.
Day override
Executes the operation for one day
operation
temporarily on another day in the 7-day
period starting from the current day.
For details, refer to Day Override
Operation on page 21.
Program check Consecutively displays the days and times when the output is set to turn ON and OFF over the course of one week in the
sequence in which the Time Switch is to operate.
For details, refer to Program Check Function on page 21.
Weekly 2-circuit Models
(H5S-W@2)
Digital quartz
1 week (7 days)
• Day, hrs (switchable between 24-hr indication and a.m./p.m. 12-hr indication), minutes, seconds
(0.00 to 23:59, 0.00 to 11:59 a.m., 0.00 to 11:59 p.m.)
• Digital indication by LCD (character height: 10 mm)
• Digital display of operation schedule during operation
• Timing chart display of operation schedule during operation
1 min
40 steps/circuit
---
---
Controls the output according to the set time of ON and OFF.
• Min. setting unit: 1 min
OFF
• Multiple-day operation also possible.
Output turns ON for a fixed period (pulse width) at the set ON time.
• Pulse width: 1 to 59 s (in 1-s increments), or 1 to 60 min (in 1-min increments)
Pulse width
• The pulse width can be set for each step.
Repeatedly turns ON and OFF during the period from the cyclic start time to the stop time.
Independent ON- and OFF-time settings are possible.
OFF
• Min. setting unit: 1 min
Stop
Adds a yearly timer operation to the weekly timer program.
For details, refer to About Yearly Programs on page 18.
Adds a yearly pulse-output operation to the weekly pulse-output program.
For details, refer to About Yearly Programs on page 18.
---
Yearly 2-circuit Models
(H5S-Y@2)
1 year (with integrated calendar to 2099)
48 steps/circuit (See note 2.)
24 steps/circuit (See note 3.)
4 yearly programs/circuit
16
Yearly 2-circuit Models (H5S-Y@2)
Yearly 4-circuit Models
(H5S-Y@4)
48 steps/circuit (See note 2.)
12 steps/circuit (See note 3.)
Yearly 4-circuit Models (H5S-Y@4)
H5S
Digital Time Switch
5

Hide quick links:

Advertisement

Table of Contents
loading