Error Settings

The BUSY signal will turn ON under the following conditions:
ERR ON
(default setting)
OFF
1. Move the cursor to SYS/Error method , and press the ENT Key.
2. Move the cursor to STEP in BUSY and press the ENT Key.
3. Move the cursor to OFF or ERR ON and press the ENT Key.
4. Move the cursor to End and press the ENT Key.
When the F400 is in Set or System Mode.
When the F400 is executing measurement or commands in Monitor or Run
Mode.
Selection
During processing (i.e.: BUSY terminal ON), if the STEP signal comes
ON, the ERR terminal will be turned ON and measurement will not be
performed.
The next time a STEP signal is input with the BUSY terminal OFF, the
ERR terminal will go OFF.
During processing (i.e.: BUSY terminal ON), even if the STEP signal
comes ON, the ERR terminal will not come ON. Measurement will not
be performed.
The Setting Window will be displayed.
White balance
Communications settings
Output
Backup
Display settings
Set key operation
Startup mode
Error method

Version

The settings will be displayed.
STEP in BUSY:
End
The setting will be saved.
STEP in BUSY:
End
The setting will be saved, and the display will return to the window shown in step
1.
STEP in BUSY: ERR ONB