Omron F3ET2 Series Operation Manual
Omron F3ET2 Series Operation Manual

Omron F3ET2 Series Operation Manual

Detection light curtain

Advertisement

Quick Links

Omron F3ET2 Series Operation Manual

Advertisement

Table of Contents
loading

Summary of Contents for Omron F3ET2 Series

  • Page 1 At the end of this document you will find links to products related to this catalog. You can go directly to our shop by clicking HERE. HERE...
  • Page 2 Cat. No. E79E-EN-01 ZX-T Series F3ET2 Detection Light Curtain OPERATION MANUAL...
  • Page 3 Manufacturer: OMRON Europe B.V. Wegalaan 67-69 2132 JD Hoofddorp, THE NETHERLANDS www.industrial.omron.eu User‘s Manual: Version 0.2 dated 18-10-2011...
  • Page 4 Precautions Precautions WARNING The F3ET2 multi-beam photoelectric sensor with beam evaluation function is not a safety component for ensuring the safety of people which is defined in EC directive (2006/42/EC) or by any other regulations or standards. GENERAL INFORMATION The instructions in this manual must be followed in order to safeguard correct installation. The barrier does not contain any parts that are subject to maintenance;...
  • Page 6: Table Of Contents

    Table Of Contents Precautions ................... 1 Chapter 1 Overview Chapter 2 Installation General....................2-2 Mechanical installation ................2-3 Operating environment ................2-4 Operating distances................2-4 Wiring & output circuit................2-5 Setting the internal selector-switches .............2-6 Chapter 3 Order codes Chapter 4 Technical specifications Ratings ....................4-2 Chapter 5 LED indicators and error indication LED indication on receiver unit...............5-2 LED indication on emitter unit..............5-3...
  • Page 8: Chapter 1 Overview

    Overview F3ET2 is a multi-beam light curtain for easy area detection for various applications. Due to its robust housing F3ET2 is also suitable for hash environments in industrial automation. F3ET2 is provided with PNP and NPN transistor output. F3ET2 is available in two resolutions: Model Sensing distance Pitch resolution...
  • Page 10 Installation 2-1 General ................2-2 2-2 Mechanical installation ..........2-3 Mounting accessories ..............2-3 Additional mounting rigidity ............. 2-3 Mechanical Mounting ..............2-4 2-3 Operating environment ..........2-4 2-4 Operating distances .............2-4 2-5 Wiring & output circuit ..........2-5 2-6 Setting the internal selector-switches ......2-6 F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 11: General

    2-1 General 2-1 General The light curtain consists of one bar with light emitting optical elements and of one with receiving optical elements. The photosensitive elements are scanned in sequence, thus broken rays are detected. F3ET2 features optical synchronisation and does not require synchronization wire between transmitter and receiver.
  • Page 12: Mechanical Installation

    2-2 Mechanical installation 2-2 Mechanical installation Mounting accessories The F3ET2 system is mechanically installed by using the T-slots on the two sides or the back- side of the housing. Use the movable bolts, washers, growers and nuts to fix the mounting brackets as shown in the picture Description movable M6 bolt...
  • Page 13: Operating Environment

    2-3 Operating environment Mechanical Mounting Please mount the light curtains in proper alignment as shown in the pictures below by using the brackets provided with the light curtains. If F3ET2 is installed at long distances the laser alignment aid F39-TGR-LLK2-CL provides a visible laser spot for simplified installation.
  • Page 14: Wiring & Output Circuit

    2-5 Wiring & output circuit 2-5 Wiring & output circuit Please connect the light curtain as described below: Variable Power Supply RECEIVER Earth Ground +24 VDC 0 VDC EMITTER Connector PIN assignment - Receiver Type Internal wiring Colour Signal name Brown White not used...
  • Page 15: Setting The Internal Selector-Switches

    2-6 Setting the internal selector-switches 2-6 Setting the internal selector- switches Precautions for Correct Use All the operations listed below must only be carried out when the receiver is disconnected to the power supply. L-ON/D-ON setting and distance setting can be changed by selector switches. To access the selector switches unscrew the end cap of the receiver and transmitter unit: There are two lines of dip switches in each transmitter and receiver.
  • Page 16 2-6 Setting the internal selector-switches DIP switch setting Transmitter: Dip-SW Status Function Not USED Not USED Not USED Not USED Not USED Not USED Not USED Not USED FAR (Default) NEAR Not USED Not USED Not USED Not USED Not USED Not USED Receiver: Dip-SW...
  • Page 18: Chapter 3 Order Codes

    Order codes F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 19 18 mm 15 m F3ET2-005-1800 5 mm 1800 F3ET2-018-1800 18 mm 15 m F3ET2-018-2100 2100 18 mm 15 m *1. Models with other dimensions and 7.5 mm pitch are available. Please con- tact your OMRON representative. F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 20: Chapter 4 Technical Specifications

    Technical specifications 4-1 Ratings................4-2 F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 21: Ratings

    4-1 Ratings 4-1 Ratings Models F3ET2-005-… F3ET2-018-… Operating distance 15 m Light source (wave length) Infrared (880 nm) Pitch 5.3 mm 18.3 mm Operation temperature –10° to +55°C Storage temperature –10° to +75°C Degree of protection IP65 (IEC 60529) Operating voltage 24 VDC ±20% Current consumption 150 mA max (excluded load on digital)
  • Page 22: Chapter 5 Led Indicators And Error Indication

    LED indicators and error indication 5-1 LED indication on receiver unit........5-2 5-2 LED indication on emitter unit........5-3 5-3 Troubleshooting for error indication ......5-4 F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 23: Led Indication On Receiver Unit

    5-1 LED indication on receiver unit Meaning of symbols SYMBOL MEANING Diagnosis LED off Diagnosis LED on Diagnosis LED blinking 5-1 LED indication on receiver unit Status of Receiver is displayed by 5 LEDs: Disposition of indicator Name of indicator Colour POWER Green...
  • Page 24: Led Indication On Emitter Unit

    5-2 LED indication on emitter unit 5-2 LED indication on emitter unit Status of Receiver is displayed by 5 LEDs: Disposition of indicator Name of indicator Colour POWER Green STATUS 1 Yellow RANGE Green Not used STATUS 2 Yellow Normal operation indication on emitter: LED signal pattern Description Emitter working, short range selected.
  • Page 25: Troubleshooting For Error Indication

    5-3 Troubleshooting for error indication 5-3 Troubleshooting for error indication Actions Check the presence of shorts on the outputs, check the correct connection of outputs Check if power supply is within specification of 24Vdc ± 20% Turn the unit ON and OFF again. If the error persist, please contact manufacturer Turn the unit ON and OFF again.
  • Page 26: Chapter 6 Dimensions

    Dimensions F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 27 L: Total length E: Detection zone A: Dead zone without detection capability All dimensions shown are in mm Item number Detection Zone E (mm) Total length L (mm) F3ET2-005-150 F3ET2-018-150 F3ET2-005-300 F3ET2-018-300 F3ET2-005-450 F3ET2-018-450 F3ET2-005-600 F3ET2-018-600 F3ET2-005-900 1013 F3ET2-018-900 F3ET2-005-1200 1272 1331 F3ET2-018-1200...
  • Page 28: Chapter 7 Accessories

    Accessories 7-1 Mounting bracket............7-2 7-2 Cables ................7-2 F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 29: Mounting Bracket

    7-1 Mounting bracket 7-1 Mounting bracket (provided with the product) 7-2 Cables Order Code Length M12-5pin XS2F-M12PVC5S2M (straight) XS2F-M12PVC5S5M M12-5pin XS2F-M12PVC5A2M (angled) XS2F-M12PVC5A5M For other accessories like alignment kit, special brackets or connector cables please contact your sales representative. F3ET2 LIGHT CURTAINS OPERATION MANUAL...
  • Page 30: Manual Revision History

    Manual Revision History The manual revision symbol is an alphabet appended at the end of the manual number found in the bottom left-hand corner of the front or back cover. Example E79E-EN-01 Revision symbol Revision Revision date Description of revision and revised page symbol January 2012 First Print.
  • Page 31 Below is a list of articles with direct links to our shop Electric Automation Network where you can see: • Quote per purchase volume in real time. • Online documentation and datasheets of all products. • Estimated delivery time enquiry in real time. •...
  • Page 32 Photoelectric sensor, Height 300mm 5mm 3m Digital 365858 F3ET2-005-300 Buy on EAN output beams Sep. Photoelectric sensor, Height 300mm 18mm 15m Digital 365859 F3ET2-018-300 Buy on EAN output beams Sep.

Table of Contents