Expressions - Omron F400 - 06-1999 Operation Manual

Color vision sensor
Table of Contents

Advertisement

Expressions

3-4
Expressions
Outputs to external devices via the terminal blocks or RS-232C can be set. Even if the
expression is not used, overall evaluation of drawn regions will be output to the OR
terminal of the terminal block.
Terminal Block Outputs
Evaluation results for each region can be output.
Measurement values for each region can be calculated and OK/NG judgement for
the calculation results can be made.
Judge0.
[R0.JG
Measurement: 28.195
Upper: [ 35.000]
Lower: [ 25.000]
:Move ENT:Change
RS-232C Outputs
Measurement values can be output.
Calculation results can be output.
The information output for output numbers 0 to 7 can be set. Information is output in
order starting from output #0.
Data0.
[R0.JG
Measurement: 28.195
ENT:Change
Output number
16 expressions (judgement output 0 to 15) can be set.
]
Output number
8 expressions (data 0 to 7) can be set.
]
Section
— Filter/Pickup —
Expression
The OK/NG judgement
for the calculation
results is output to the
terminal block.
Calculation result for
displayed image.
Evaluation criteria
The evaluation criteria
for the expression are
set. (–9999999.999 to
9999999.999)
Expression
Calculation results of
displayed image
3-4
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

F400