High-speed Counter/Pulse Output
Instructions

INI

Instruction
monic
MODE CONTROL
INI
Symbol
Applicable Program Areas
Function block
Area
definitions
Usage
OK
Operands
Operand
P
Port specifier
C
Control data
NV
First word with new PV
P: Port Specifier
P
0000 hex
Pulse output 0
0001 hex
Pulse output 1
0010 hex
High-speed counter 0
0011 hex
High-speed counter 1
0100 hex
Interrupt input 0 in counter mode
0101 hex
Interrupt input 1 in counter mode
0102 hex
Interrupt input 2 in counter mode
0103 hex
Interrupt input 3 in counter mode
1000 hex
PWM(891) output 0
1001 hex
PWM(891) output 1
CS/CJ/NSJ Series Instructions Reference Manual (W474)
Mne-
Varia-
Function
tions
code
@INI
880
Block program areas
Step program areas
OK
OK
Description
Function
INI(880) can be used to execute the following operations
• To start comparison with the high-speed counter comparison table
• To stop comparison with the high-speed counter comparison table
• To change the PV of the high-speed counter.
• To change the PV of interrupt inputs in counter mode.
• To change the PV of the pulse output (origin fixed at 0).
• To stop pulse output.
INI
INI(880)
P: Port specifier
P
C
C: Control data
NV
NV: First word with new PV
Subroutines
Interrupt tasks
OK
Port
3. Instructions
SFC action or transition
programs
OK
OK
Data type
Size
WORD
1
UINT
1
DWORD
2
727