1.
Remove the two Phillips M2.0 × 2.5 screws (1) that secure the fingerprint reader and bracket to
the computer.
2.
Remove the fingerprint reader bracket (2) from the computer.
The fingerprint reader bracket is included in the Bracket Kit, spare part number N96233-001.
3.
Remove the fingerprint reader (3) from the computer.
To replace the fingerprint reader, reverse the removal procedures.
Fingerprint reader cable
To remove the fingerprint reader cable, use this procedure and illustration.
The fingerprint reader cable is included in the Cable Kit, spare part number N96591-001.
Before removing the fingerprint reader cable, follow these steps:
1.
Prepare the computer for disassembly (see
2.
Remove the bottom cover (see
3.
Remove the battery (see
4.
Remove the WWAN module (see
5.
Remove the SSD (see
6.
Remove the fan (see
7.
Remove the system board (see
8.
Remove the fingerprint reader (see
Remove the fingerprint reader cable:
1.
Release the ZIF connector (1) the fingerprint reader cable is connected to, and then disconnect the
fingerprint reader cable from the fingerprint reader.
80
Chapter 6 Removal and replacement procedures for authorized service provider parts
Preparation for disassembly on page
Bottom cover on page
Battery on page
54).
WWAN module on page
Solid-state drive on page
Fan on page
57).
System board on page
Fingerprint reader on page
42).
45).
47).
62).
79).
54).