Payment System Lock; Clear Paid Signal; Debounce Time; Pay System Override Time - Miele PDR 908 HP Operating And Installation Instructions

Heat-pump dryer
Table of Contents

Advertisement

Supervisor level

Payment system lock

To avoid tampering, a programme lock
can be set up in programme operation.
If the lock is applied, the programme is
interrupted and payment credit is lost
as soon as the door is opened.
The time for the lock to be applied can
be adjusted to enable laundry to be ad-
ded.
- Factory default: off
- As soon as the programme starts
- 1–5 minutes after the start of the pro-
gramme

Clear paid signal

The "Paid" signal in coin box mode can
be applied until the end of the pro-
gramme or discarded if the programme
is not started after 5 minutes.
- Factory default: Off
- On

Debounce time

In coin mode, the debounce time for
the minimum payment signal that
must be applied can be adjusted.
- Factory setting: Short
For coin boxes where the falling coin
generates the paid pulse.
- Long
For central control units on a 230 V
basis.

Pay system override time

Setting the transition signal for the
coin box. Security time margin to pre-
vent the coin box being tampered with.
110
The override time can be set or
switched off in increments of one
minute from 30 minutes up to four
hours.
If the programme does not end within
the override time, the coin box setting is
reset. The programme is cancelled.
Factory default: 3 hours