Models With Firmware 6.06 And Later For Non-Dms Models. Models With Firmware 7.09 And Later For Dms Models - Graco G3-G-24MX-2L0L00-10CV00R0 Instructions Manual

Max automatic lubrication pump
Hide thumbs Also See for G3-G-24MX-2L0L00-10CV00R0:
Table of Contents

Advertisement

Advanced Programming
3. Press the ENTER button.
A11- Warning Off Through Alarm Relay
This function changes the behavior of the alarm output
in a warning condition to always off.
Fault and Warning LEDs Illuminate
F
. 44
IG
1. The default OFF is
displayed. The alarm
output will turn on
during a warning
condition.
2. Press the UP or DOWN
ARROW to change OFF to
ON on the display to change
the alarm output to be off
during a warning condition.
3. Press the ENTER button to exit
Advanced Programming.
56
Models with Firmware 6.06 and
later for non-DMS models.
Models with Firmware 7.09 and
later for DMS models
A12 - Prelube Sequences
This function changes the behavior of the prelube func-
tion to add more lubrication sequences upon pump
start up. While running multiple sequences, after the ini-
tial sequence, PL:xx will be displayed showing how
many sequences are left.
Note: if pump has option "08" and using a pressure
switch with multiple sequences, a vent delay time must
be programmed under Advanced Programming Option
A3.
Prelube LED illuminates (F
F
. 45
IG
1. The default 0001 is displayed.
When Prelube is on, it will run
one sequence.
2. Press the UP or DOWN
ARROW button until desired
number of prelube
sequences displays.
. 43)
IG
332305R

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3-g-24mx-2lfl00-10cv00r0G3-g-acmx-2l0l00-1d0v0000G3-g-acmx-2lfl00-1d0v0000G3-g-12mx-2l0l00-1dmva2r3G3-g-24mx-2l0l00-1dmva2r3G3-g-24mx-2lfl00-1dmva2r3 ... Show all

Table of Contents