Max Model Setup

Max Model Setup
Control Panel Overview (F
NOTE: Programming instructions begin on page 33.
ON TIME/BACKUP TIME
LED lights when ON
Time/Backup Time is running.
Display shows time as MM:SS
(minutes and seconds).
i.e., 08:30 is 8 minutes: 30 sec-
onds.
Sets the limits for the amount
of time to complete a cycle or
build up pressure before a
warning is activated.
Counts down from a set time
to zero.
CYCLE / PRESSURE SETUP
Sets either Cycle (C) or Pressure
(P) Monitoring limits for up to 3
sensors.
Each sensor is set up and con-
trolled independently.
All three LEDs blink if the vent
valve output is on.
MACHINE COUNT
LED lights when Machine Count
is used to control Pump OFF
function.
Counts independent machine
operations with a sensor to con-
trol Pump Off duration.
Time OFF function can be used
as a backup for Machine Count.
LEFT DIRECTION ARROW /
RESET
In SETUP MODE: moves cursor
in display one field to the left.
In RUN MODE: single press
clears warning.
In RUN MODE: pressing for one
second ends run cycle if no
warnings.
In ALARM MODE: pressing and
holding for 3 seconds clears
fault / warning and switches
cycle to OFF MODE.
F
. 34
IG
32
. 34)
IG
DISPLAY
A blinking LED under HH, MM, SS
or ## identifies type of measure-
ment unit you are setting; i.e., HH is
hours.
A blinking number on the display
indicates the G3 is in SETUP
MODE.
In RUN MODE displayed numbers
count up or down. See Time ON
and Time OFF.
UP and DOWN ARROW
Hold both the UP and DOWN ARROW but-
tons down together for 3 seconds to enter
SETUP MODE.
In SETUP MODE: increases or decreases
number values shown in display.
OFF TIME/BACKUP TIME
LED lights when OFF
Time/Backup Time is used to
control Pump OFF function.
Value is entered in HH:M.
Displays in HH:MM (hours and
minutes) when > 1 hour.
Times pump rest between cycles.
Counts down from set time to
zero.
Can be set up to use as a backup
for Machine Count control.
ALARM ICONS
LED next to icon lights when a
fault / warning event occurs
during a run cycle. See page 63
for a complete description of
these alarm scenarios.
PIN ICON
LED next to icon lights
indicating PIN is required
to enter setup.
In SETUP MODE LED
lights when setting up the
PIN.
PRELUBE
LED next to icon lights indicat-
ing LED lights when Prelube
function is enabled.
RIGHT DIRECTION ARROW /
MANUAL RUN / ENTER
In SETUP MODE: saves entry,
moves cursor in display one
field to the right or to the next
setup step.
In RUN MODE: starts a man-
ual run cycle.
332305R