Error Log - Graco G3-G-24MX-2L0L00-10CV00R0 Instructions Manual

Max automatic lubrication pump
Hide thumbs Also See for G3-G-24MX-2L0L00-10CV00R0:
Table of Contents

Advertisement

Operation / Data Log
Example Event Log 2: Pump cycle of an injector valve
system with a pressure switch feedback.
Date
Time
9/29/2010
13:28:12
9/29/2010
13:23:12
9/29/2010
13:23:11
9/29/2010
13:23:11
9/29/2010
13:22:20
Common System Events are listed below.
Pump Run On
The pump entered an on cycle and is
operating and dispensing material.
Pump Run Off
The pump entered an off cycle and is
not dispensing.
Pump Run Can-
A pump on cycle was canceled by
celed
pressing the cancel button on the front
panel and holding it for 3 seconds.
Power On
The pump powered on.
Power Off
The pump powered off.
Program Variable
The setup mode was entered.
Change
C1 Cycle Detected
The system is set up to monitor a prox-
imity switch on a divider valve using the
C2 Cycle Detected
sensor input (C1, C2, and/or C3) and
C3 Cycle Detected
has detected one divider valve cycle.
C1 Cycle Com-
The system is set up to monitor a prox-
pleted
imity switch on a divider valve using the
sensor input (C1, C2, and/or C3) and
C2 Cycle Com-
has achieved the number of counts
pleted
required by the system for that input,
C3 Cycle Com-
completing a pump on cycle.
pleted
P1 Pressure Com-
The system is set up to monitor a pres-
pleted
sure switch for an injector system using
sensor input (P1, P2, and/or P3), the
P2 Pressure Com-
system has achieved pressure and the
pleted
switch has activated, completing a
P3 Pressure Com-
pump on cycle.
pleted
Machine Count
The system is set up to monitor a sen-
Completed
sor on the equipment being lubricated
using the machine count input and has
achieved the number of counts
required by the system for that input,
completing a pump off cycle and initiat-
ing a pump on cycle.
Local Manual Run
The manual run button was pressed,
Initiated
initiating a pump on cycle.
Remote Manual
The remote manual run button was
Run Initiated
pressed initiating a pump on cycle.
44
Description
Venting Completed
Venting Detected
Pump Run Off
P1 Pressure Completed
Pump Run On
Venting Detected
In an injector system, the pump on
cycle has completed and the system is
currently venting pressure through the
vent valve.
Venting Completed
in an injector system, the system com-
pleted the vent time.
Prelube Initiated
The pump has entered a prelube delay
after powering up.
Prelube Delay Com-
The pump has completed prelube delay
pleted
and will begin a pump on cycle.
Successful Pin
The pin code was successfully entered
Code Entry
and the user has entered setup mode.
Firmware Update
The firmware was updated.
Completed
Low Power Fault
The power source does not have
Pump On
enough power to power the pump
when it turns on. Replace power source
Low Power Warning
The voltage of the power source
Cleared
dropped below an acceptable thresh-
old. The warning was cleared either by
user intervention, or by self-correction.
Low Power Fault
The voltage of the power source
Cleared
dropped below and acceptable thresh-
old for longer than 15 minutes and the
pump failed out. The fault was cleared
by the user.

Error Log

The Error Log lists Set Time and Clear Time for the last
400 faults and warnings. The most recent event is listed
first.
The log file is stored as:
GRACO/{DMS_id}/{download date - YYYYm-
mDD}/ERRORLOG.CSV
Example: GRACO/00025/20100911/ERRORLOG.CSV.
332305R