A9 - Toggle Low Level Output on Low Level
Warning or Fault
This function changes the behavior of the low level out-
put in a warning or fault from either steady on (default)
or toggling once every second.
Low Level and Warning LEDs Illuminate
F
. 42
IG
1. The default OFF is
displayed. The alarm
output will toggle
once a second.
2. Press the UP or DOWN
ARROW to change OFF to
ON on the display to change
the alarm output to be on
steady.
3. Press the ENTER button to exit
Advanced Programming.
332305R
Models with Firmware 6.03 and
later. DMS Models with
Firmware 7.07 and later.
A10 - Low Level Reset Upon Power On.
This function changes the behavior of the low level
upon pump power on. When A10 is on, a low level fault
clears when the pump power is cycled. The pump will
revolve 5 revolutions, checking to see if the low level
condition is still present. If not, it will self clear and con-
tinue. If a low level condition exists during the 5 revolu-
tions, it will go into a low level fault.
Low Level ON LED illuminates (F
F
. 43
IG
1. The default OFF is displayed. The
alarm output will toggle once a
second.
2. Press the UP or DOWN
ARROW button to change
OFF to ON on the display to
change the low level reset
upon power on.
Advanced Programming
. 43).