Advanced Programming

There are 11 Advanced Programming options. The following Table Identifies each option and when it is used.
Advanced
Model
Option
A1
Max
Lockout
Code (Optional)
A2
Max
Low Level Alarm
Time
A3
Max
Vent Valve Time
A4
Max
Alarm Retry
A5
Max
Active Alarm
A6
Functional and
DMS
Technical User
Equipped
Summary Reset
Models
A7
Max
Constant Alarm
Output on Fault
Firmware 6.02 and later
A8
Max
4 Digit Hour Off
Time
A9
Max
Toggle Low Level
and
Output on Warning
"08" option
or Fault
332305R
Setting
Format/ Description
Secures setup modes with PIN
MM:SS (minutes:seconds) sets
amount of time between Low
Level Warning to Low Level
Fault.
Default = 3 minutes
MM:SS (minutes:seconds) sets
amount of time vent valve stays
open after Pump ON Mode.
Default = 5 minutes
Sets number of automatic
retries after a Cycle or Pressure
Alarm.
Default = 0
Changes alarm output behav-
ior.
Default = OFF
Clears the Functional and
Technical User Summaries
Changes alarm output behav-
ior.
Default = OFF
Changes maximum OFF time.
Default = OFF
Changes Low Level Indication
behavior.
Default = OFF
Advanced Programming
Why Use This?
Prevents unauthorized users to adjusting set-
tings.
To accommodate most lubrication situations, a
conservative amount of time is programmed
between the low level warning and fault to help
protect unit from running dry. If necessary the
amount of time the unit runs before stopping
due to a low level fault can be adjusted.
In an injector based system that does not use
a sensor for feedback, determines the amount
of time the system vents.
Vent time can be modified.
Establishes the number of times the unit auto-
matically retries lubricating after a cycle or pres-
sure alarm to determine if a temporary or false
signal can be cleared.
Uses alarm output to determine if a unit has an
alarm AND/OR loses power.
The output turns ON when power is applied. It
turns OFF when power is lost or an alarm
occurs.
Normal operation (OFF) will only activate alarm
output in an alarm condition when power is on.
Can change (set to ON) to activate alarm with
power ON and deactivate with power OFF OR
warning.
Used to manage power outage.
Allows user to track lube events from a specific
point (reset), i.e. a month to month evaluation.
This function changes the behavior of the alarm
output in a fault from either toggling once every
second or steady on.
This function changes OFF time from HH:MM to
HHHH. It allows a maximum of 9999 hours of
OFF time.
This function changes the behavior of the low
level output in a warning or fault from either
steady on or toggling once per second.
49