COMSPHERE DualFlow Data Service Units
Results
Reported By
Time:
Local and remote DBM
Tot Block:
Local and remote DBM
Rx Blk err:
Local and remote DBM
Tx Blk err:
Local and remote DBM
Rx TimOuts:
Local DBM only
1
Local refers to the test initiator.

Bit Error Rate Test

The Bit Error Rate Test (BERT) is a session-
disruptive test that transmits a 511-bit pattern. It analyzes
the network circuit. It can monitor the results by putting
the remote DSU or DBM into Digital Loopback and
checking the returned pattern for errors, or by
simultaneously executing a BERT in the local DSU.
The test continues until aborted from the DCP or NMS.
If nondisruptive diagnostics are in effect (if Diag Type
is set to NonD), diagnostic data can be disrupted.
To display the results of the test, press F2 to select
Displ. The results are shown in Table 4-5. To clear the
results of the test and clear the counters to zero, press F3
to select Clr.
4-12
Table 4-4

End-to-End Test Results

1
Running test timer. (The Clr selection resets the timer to 0:00:00.)
Number of blocks completed. (The Clr selection resets the counter to 0.)
Number of incoming blocks with errors detected, indicating a fault in the
incoming transmission path. (The Clr selection resets the counter to 0.)
Number of blocks with errors detected at the remote DSU, indicating a
fault in the outgoing transmission path. (The Clr selection resets the
counter to 0.)
Number of blocks that were not received or acknowledged by the
remote DSU or DBM. (The Clr selection resets the counter to 0.)
Time:
Tot Error:
Err Secs:
July 1999
Information Displayed
Table 4-5

Bit Error Rate Test Results

Results
Information Displayed
Running test timer. (The Clr
selection resets the timer to
0:00:00.)
Running count of bits in
error; Max, if the maximum error
count has been reached, which
is 64000. (The Clr selection
resets the counter to 0.)
Running count of errored
seconds. Errored second is at
least one error is detected during
a 1-second time period. (The Clr
selection resets the counter to
0.)
3615-A2-GB20-40