Dial Backup Error Messages - Paradyne COMSPHERE DualFlow 3615 User Manual

Data service units
Hide thumbs Also See for COMSPHERE DualFlow 3615:
Table of Contents

Advertisement

Message
Notify NMS
DBM: Busy
DBM: Call Aborted
DBM:Callbck Fail
DBM:
Conflict w/Envir
DBM:Dir Empty
DBM:DTR Discon
DBM:Illegal Char
DBM:No Answer
DBM:NetwkAbort
DBM:Netwk Busy
DBM:NetwkUnavl
DBM:NoDialTone
1
If Yes, an error message is reported to the NMS if the NMS initiated the dial command.
3615-A2-GB20-40
Table C-9
(1 of 2)

Dial Backup Error Messages

1
Condition
Yes
Telephone line associated with
remote DBM is busy.
No
Call was aborted from the DCP.
No
There was a failure to connect
on a callback attempt.
Yes
DBM is not able to dial out (e.g.,
test is being run); there is no
DBM at the far end.
Yes
An attempt was made to place a
call from an empty directory.
Yes
DTR has gone low, or the call
did not connect.
Yes
Illegal character in the directory
specified.
Yes
There was no answer from the
remote DBM or modem.
No
Call was aborted by the
network.
Yes
Call was unable to place call at
the time.
Yes
Network is incapable of passing
data.
Yes
No dial tone received from the
network.
July 1999
Status Indicators and Control Panel Messages
Action
Try again. Try another number if possible,
or investigate why the line is busy.
None
Make sure you have the correct call setup
pointer and that remote DBM has the
proper telephone number in that directory.
If both are correct, attempt to place a
manual call from the remote DBM.
Wait until the test is completed, or abort
the test.
Check Backup Directory entries and
numbers.
Raise DTR at the DTE, or disable the
DTRCallCon configuration option.
Check directory entry.
1. Check that remote DBM is configured
for many calls.
2. Make sure remote DBM is properly
connected to the dial (PSTN) network.
3. Check operational status of remote
DSU using a Device Test.
4. Attempt to place a call from remote
DBM. If it cannot be placed, replace
the DBM.
Try again.
Try again.
Look for line problems. If conditions are
good and no problem is found, call
telephone company and report the
problem.
Check the dial (PSTN) network
connections. If conditions are good and
no problem is found, call telephone
company and report the problem.