Model 3615 Dsu Dds (Lads); Lads Connection Distances - Paradyne COMSPHERE DualFlow 3615 User Manual

Data service units
Hide thumbs Also See for COMSPHERE DualFlow 3615:
Table of Contents

Advertisement

COMSPHERE DualFlow Data Service Units
"
Procedure
1. Plug the DDS network interface cable into the
DSU jack labeled LINE.
U.S. – select either end of the cable
Canada – select the 8-pin end
2. Plug the other end of the cable into the modular
jack (USOC RJ48S) provided by the circuit
provider.
If the remote DSU is also connected to the network, the
DSU's green OK indicator lights and the Alrm indicator
goes off. The Health and Status screen no longer displays
a No Signal message.
If connecting the DSU to a LADS network, there are
distance limitations that govern the use of DSUs on the
network. Table 2-2 summarizes these limitations.
Data Rate
Data Rate
(kbps)
2.4
4.8
9.6
1
19.2
38.4
56
64
1
Power level is –10 dBm.
2-8
Table 2-2

LADS Connection Distances

Wire Gauge (AWG)
19
22
20.0 mi
16.6 mi
(32.2 km)
(26.7 km)
19.4 mi
12.7 mi
(31.2 km)
(20.5 km)
15.2 mi
9.7 mi
(24.5 km)
(15.6 km)
11.8 mi
7.5 mi
(19.0 km)
(12.1 km)
11.2 mi
6.5 mi
(18.0 km)
(10.5 km)
9.2 mi
5.4 mi
(14.8 km)
(8.7 km)
9.2 mi
5.4 mi
(14.8 km)
(8.7 km)
July 1999
Figure 2-6. Model 3615 DSU DDS (LADS)
Network Connection
24
26
12.7 mi
9.4 mi
(20.5 km)
(15.1 km)
9.6 mi
7.1 mi
(15.4 km)
(11.5 km)
7.3 mi
5.6 mi
(11.7 km)
(9.0 km)
5.7 mi
4.2 mi
(9.2 km)
(6.8 km)
4.6 mi
3.2 mi
(7.4 km)
(5.1 km)
3.8 mi
2.8 mi
6.2 km)
(4.5 km)
3.8 mi
2.8 mi
(6.2 km)
4.5 km)
3615-A2-GB20-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere dualflow 3616

Table of Contents