COMSPHERE DualFlow Data Service Units
Verifying the Network
Perform a Health and Status check on the DDS circuit
to ensure that the network is functioning.
"
Procedure
1. Select Local (F1).
2. Select Stat (F1).
3. Select H/S (F1).
4. Select Devic (F1).
5. Press the
key to return to the top-level menu.
6. Select Local (F1).
7. Select Bckup (F2).
8. Select DrBU to drop the backup call.
No error messages should appear. Refer to
Appendix C, the
Device Health and Status Messages
section, should there be a problem with the DDS Line.
2-12
Other Tests
The following lists the tests available on your DSU.
Refer to the
Test Branch
test information, as well as more detail on how to
configure and operate the DSU. Refer to
determine how best to access each test.
Device Test (Devic)
Local Loopback (LL) – DSU only
DTE Loopback (DTE)
Digital Loopback (DL)
Remote Digital Loopback (RL) – DBM only
Bilateral Loopback
Digital Test (DT) – DBM only
End-to-End Test (EE) – DBM only
Bit Error Rate Test (BERT)
Lamp Test (Lamp)