COMSPHERE DualFlow Data Service Units
Specifications
APPLICATION
COMMUNICATION LINE
PORT RATES
DATA RATES
DBM COMPATIBILITY
SWITCHED 56 KBPS
NETWORK INTERFACE
3615 DualFlow DSU
3616 DualFlow DSU
APPROVALS
DOC
Certification Number
Load Number
NETWORK COMPATIBILITY
Equipment Warranty
and Support
If you experience trouble with this equipment, please
contact your sales or service representative (as
appropriate) for repair or warranty information. If the
product needs to be returned to the company service
center for repair, contact them directly for return
instructions using one of the following methods:
Via the Internet: Visit the Paradyne World Wide
Web site at http://www.paradyne.com
1-8
Table 1-5

2-Wire Switched 56 DBM Technical Specifications

Full- or half-duplex data transmission via 56 kbps switched services
compatible with AT&T, US SPRINTr, and MCIr using DataPatht 2-wire
switched access to a local exchange carrier (LEC) or an interexchange
carrier (IEC)
A dedicated 2-wire access or a local exchange carrier 2-wire switched
access
Async or Sync rates: 56, 48, 38.4, 32, 28.8, 19.2, 18.8, 18.0, 16.8, 14.4,
12.0, 9.6, 9.2, 8.4, 7.2, 4.8, 4.4, 4.0, 2.4, 2.0, and 1.2 kbps
Other asynchronous rates (e.g., 150, 300, 600, and 1800 bps) can be
obtained through oversampling
Asynchronous rates support ITU-T V.14 extended rate range at
8 to 12 bits per character, including the start and stop bit (+2.3, –2.5
percent overspeed/underspeed compensation at 10 bits per character)
56 kbps (Note that the 2-wire Switched 56 DBM or 3600 Series DBM-D
uses proprietary rate adaption to support data rates of less than
56 kbps.)
If Call Setup is set for Callback or Password security, then the device is
compatible with a 3600 Series Switched 56 DBM only.
If Call Setup is set for Alarm or None, then any Switched 56 kbps
terminal interface unit (TIU) can be used.
6-pin modular jack, USOC SJA48
(One or two) 50-pin connector
230 5870 A
0
Northern Telecom NIS S204-2e 1986
July 1999
Criteria
Via Telephone: Call our automated call system to
receive current information via fax or to speak with
a company representative.
— Within the U.S.A., call 1-800-870-2221
— Outside the U.S.A., call 1-727-530-2340
3615-A2-GB20-40

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comsphere dualflow 3616

Table of Contents