When a DBM (control or tributary) originates Remote
Digital Loopback, both the originating DBM and the
targeted DBM enter Test mode. No other test can be run at
the originating DSU or the targeted DSU until the Remote
Digital Loopback is aborted.
The DBM does not generate test results.
NOTE
To activate a V.54 Loopback from
the NMS to a DSU, first enable
V.54 Lpbk (DSU option set) at
both the control and tributary
DSUs. Then, select
3600 remote-digital at the NMS,
not V.54-remote-digital.

Bilateral Loopback

Bilateral Loopback (Bilat Lpbk) is a combination of
DTE and Digital Loopbacks operating simultaneously in
the same DSU. Both Bilateral and Digital Loopbacks are
selected from the DSUpt (DSU Port) or DBMpt (DBM
Port) option set.
NOTE
If Bilat Lpbk is enabled,
requesting a Remote Digital
Loopback or Digital Test will
automatically initiate a DTE
Loopback, as well.

Digital Test

Only available to a DBM, the Digital Test (DT) checks
the functionality of a pair of DBMs. This test is run on the
DBM over the backup connection to a remote DBM for
point-to-point testing.
The remote DBM is placed in Digital Loopback, then
the local DBM transmits the 511-bit test pattern over the
network to the remote DBM for an operator-specified
length of time.
3615-A2-GB20-40
During the test, the TXD, RXD, and RTS LED
indicators show the states of the leads at the DTE
interface if the DBM port leads are being displayed. At
the conclusion of the test, the local DSU releases the
remote DBM from Digital Loopback.
To review the results of the test, select Displ (Display)
and press the
key to scroll through the results shown
in Table 4-3.
When the test is over, the top line displays Final
instead of Active.

Digital Test Results

Results
Time:
Tot Error:
Err Secs:

End-to-End Test

Only available to the DBM, the End-to-End (EE) Test
analyzes a control and a tributary DBM, and the network
circuit between them in both directions independently. It
transmits fixed packets (or blocks) of data between the
DBMs When an End-to-End Test is run, diagnostic data
may be disrupted.
To view the results of the test, select Displ (Display)
and press the
key to scroll through the results shown
in
Table
4-4.
When the test is over, the top line displays Final
instead of Active.
July 1999
Operating the DSU
Table 4-3
Information Displayed
Running test timer. (The Clr
selection resets the timer to
0:00:00.)
Running count of bits in error;
Max, if the maximum error
count has been reached, the
maximum being 64000. (The
Clr selection resets the counter
to 0.)
Running count of errored
seconds. (The Clr selection
resets the counter to 0.)