COMSPHERE DualFlow Data Service Units
Message
Notify NMS
DBM:No Ringing
DBM:
NotConnected
DBM:ProtoErr nn
DBM:
RateMismatch
DBM:SecurityFail
1
If Yes, an error message is reported to the NMS if the NMS initiated the dial command.
C-12
Table C-9
(2 of 2)
Dial Backup Error Messages
1
Condition
No
DBM is not getting ringback
from the other end.
No
Call attempt failed for
unspecified reasons.
No
Protocol error ( nn is the error
number) by the 2-wire Switched
56 DBM.
Yes
The rate in the calling and
called DBM or modem are not
compatible.
No
Passwords in calling and called
DBM do not match.
July 1999
Action
Look for line problems. If conditions are
good and no problem is found, call
telephone company and report the
problem.
1. Check DBM for proper operation by
running a Device Test.
2. Check the DBM's configuration options
to ensure that DBM is enabled.
3. If you cannot correct the problem,
contact your service representative.
1. Check the lines. Line quality has
degraded. (A call to the central office
to perform diagnostic tests may be
required.)
2. If the line quality is good, note the
protocol error number and whether the
DBM was originating or answering a
call, then contact your service
representative.
Check speed configured in both units.
1. Make sure that both DBMs have
compatible security options.
2. Make sure that both DBMs have the
proper password.