Alarm Output Connection - Paradyne Compshere 3000 Series Installation Manual

Carrier
Hide thumbs Also See for Compshere 3000 Series:
Table of Contents

Advertisement

Alarm Output Connection

To connect the alarm output to an external light or
buzzer:
Install the alarm light or buzzer and voltage source
as described in the instructions received with the
light/buzzer and voltage source.
Use the two ALARM terminals labeled E1 and E2
at the rear of the carrier to install two external
device leads.
Customer
Supplied
Voltage
Source
Rear of Cabinet
Carrier 6
Carrier 5
Carrier 4
Carrier 3
SGRD
FGRD
Carrier 2
Carrier 1
3000-A2-GA31-D0
Customer
Supplied
Alarm Light
or Buzzer
E4
ALARM
E3
E1
E2
To Next
Cabinet
495-12261-02
Installing the Carrier and Assembly Components
"
Procedure
1. Use pliers to pull the plastic covers off the E1 and
E2 terminals.
Plastic Cover
2. Insert the end of the wire coming from the voltage
source and the end of a wire to be connected to the
next carrier into the E1 terminal. It is not
necessary to strip the wires.
Wire Ends
3. Fit the wires into the slot in the terminal. Replace
the plastic cap on the terminal, fitting the wires
into the matching slot cut lengthwise in the cap.
The last carrier to be connected
has one incoming lead for each
terminal.
Cover Slot
July 1999
E 2
496-14656a-01
Tube Slot
Hollow Tube
496-14919b
NOTE
496-14919c
3-15