COMSPHERE 3000 Series Carrier

Overview

The COMSPHERE 3000 Series Carrier is a metal
enclosure that has seventeen slots for installing circuit
cards. The Shared Diagnostic Unit (SDU) uses Slot 0; the
other sixteen slots are for devices. This number is reduced
by one slot for:
Dial/lease multiport modems, which occupy two
slots.
DSU with MUX card. The MUX card for TDM or
MCMP is physically attached to a DSU, and the
two cards occupy two slots.
Digital bridge applications, where each DBM-X
also occupies a separate slot.
Slot Numbers
SDU 1
2
15
16
3000
Shared Diagnostic
Control Panel
(SDCP)
3-2
SDU
Slot 0
Circuit
Card
Captive
Screws
Figure 3-1. 3000 Series Carrier and Components
July 1999

Standard Carrier Equipment

Each carrier is shipped with the items listed below
bundled in a plastic bag:
Six cable ties
Two fuses (spares)
Four # 10-32 mounting screws
Four cabinet # 12-24 mounting screws and four
speed nuts for use with other cabinets
One jumper wire for the frame ground/signal
ground
In addition, the carrier is shipped with a power cord
and power transformer unit. Figure 3-1 shows a fully
loaded carrier.
3000 Series
Carrier
AC Power
Transformer
Unit
Fan Module
(optional)
Brackets Set for
19-Inch Cabinet
496-13596-05
3000-A2-GA31-D0